The WZ11 series is a split-type DC charging pile designed in accordance with the standards of State Grid. The standard version is 320kW as per the national standard.
Flexible power combination scheme: The power of the rectifier host is selectable from 320 to 480kW, with a single node output power of 40kW. Multiple nodes can be combined for use to increase the output power.
2. High-power liquid-cooled ultra-fast charging: The liquid-cooled charging terminal can carry a larger charging current and is adapted to a greater charging power, with a peak charging power of up to 600kW and a charging rate of 1C to 5C.
3. High compatibility: Supports five mainstream interfaces (GBT/CCS1 / CCS2 / CHAdeMO/NACS), and the communication protocol is the current mainstream OCPP1.6 / OCPP2.0. It has been adapted to multiple charging station management platforms (YKC, TELD, etc.), and is compatible with both lithium iron phosphate batteries and lithium batteries.
4. Customization: You can contact the customer manager to customize the color combination and advertising paint work you like.
Mian
cabinet
|
Product Number |
WZ11Z-320kW |
WZ11Z-480kW |
|
Input |
275-490VAC (3P+N+PE) || 50/60Hz |
|
|
Output Voltage |
200 - 1000VDC |
|
|
Output current |
0-1050A |
0-1600A |
|
Max power |
320KW |
480kW |
|
Parallel Charge Mode (Optional) |
40 kW per Port |
|
|
Load ports number |
8 |
12 |
|
Operating temperature |
-30°C to 55°C |
|
|
Altitude |
< 2000m |
|
|
Working || Storage Humidity |
≤ 95% RH (Non-condensing) |
|
|
Ingress Protection |
IP54 |
|
|
Power Electronics Cooling |
Air Cooled |
|
|
Insulation (input - output) |
>2.5kV |
|
|
Communication |
Ethernet – Standard || 3G/4G Modem (Optional) |
|
|
Electrical Safety: GFCI |
RCD 30 mA Type A |
|
|
Electrical Safety: Surge Protection |
20 kA |
|
|
Protection |
Over voltage protection, lightning protection, overcurrent protection, leakage protection, waterproof protection, etc. |
|
Changing terminal
|
Product Number |
WZ11T-600kW |
|
Input |
200 - 1000VDC |
|
Output Voltage |
200 - 1000VDC |
|
Output current |
0-600A |
|
Max power |
600KW |
|
Connector |
GBT/CCS2/CHAdeMO/CCS1/NACS(Tesla) |
|
Connector number |
1 |
|
Charging rate |
5C |
|
Operating temperature |
-30°C to 55°C |
|
Altitude |
< 2000m |
|
Working || Storage Humidity |
≤ 95% RH (Non-condensing) |
|
Ingress Protection |
IP54 |
|
Power Electronics Cooling |
Liquid-cooling |
|
Insulation (input - output) |
>2.5kV |
|
Communication |
Ethernet – Standard || 3G/4G Modem (Optional) |
|
Electrical Safety: GFCI |
RCD 30 mA Type A |
|
Electrical Safety: Surge Protection |
20 kA |
|
Protection |
Over voltage protection, lightning protection, overcurrent protection, leakage protection, waterproof protection, etc. |