服务热线:13867748881
首页 >> 产品中心 >> 配电自动化馈线终端(FTU)
配电自动化馈线终端(FTU)
出口经济版重合闸控制器-economic type controller
产品简介
This ROCKWELL economic type controller which is used for medium voltage overhead line monitoring and controlling, which can be equipped with pole mounted switchgear achieve of automatic monitoring, fault analysis and event records, and drive switch to isolate off line fault, recovery gird safety running.
It’s suitable for up to 35kV outdoor switchgear using, include: vacuum circuit breakers, oil circuit breakers and gas circuit breakers.
This type of product gathering with all the functions like:
line protection, controlling, measurement and monitoring of voltage and current signals.
出口经济版重合闸控制器-economic type controller的概述
    出口经济版重合闸控制器是中压架空线路电网的监控单元,与柱上开关配合实现线路状态自动监控、故障分析、判断记录,具备驱动开关保护线路设备安全,切断线路故障及自动恢复线路运行等功能。适用于35KV及以下户外开关设备,包括真空断路器,油断路器及气体断路器。

    出口经济版重合闸控制器是集线路保护、控制、电压电流信号测量、监视于一体的综合自动化户外测控装置。

    This ROCKWELL economic type controller which is used for medium voltage overhead line monitoring and controlling, which can be equipped with pole mounted switchgear achieve of automatic monitoring, fault analysis and event records, and drive switch to isolate off line fault, recovery gird safety running. 

    It’s suitable for up to 35kV outdoor switchgear using, include: vacuum circuit breakers, oil circuit breakers and gas circuit breakers. 

    This type of product gathering with all the functions like:

line protection, controlling, measurement and monitoring of voltage and current signals.
出口经济版重合闸控制器-economic type controller的功能 

1、具有速断、限时速断、定时限过流的三段式保护功能;

2、具有手合加速段保护功能,断路器合于故障加速跳闸,并闭锁合闸;

3、具有0~4次自动重合闸功能,满足“分-t1-合分-t2-合分-t3-合分-t4-合分-闭锁”工作特性,具有重合闸后加速功能,重合次数、延时可自由设定;

4、具有零序保护功能,能判断小电流故障;

5、具有涌流抑制保护功能;

6、具有PT过压分闸保护功能;

7、具有PT失压分闸保护功能; (根据用户需求添加)

8、具有得电合闸保护功能;

9、具有频率保护功能;

10、具有预付费保护功能; (根据用户需求添加)

11、具有储能告警功能;

12、其它功能:事件记录、实时时钟、实时状态查询;

13、可选功能:SOG保护功能、双PT功能、CT防开路功能、智能手机控制(蓝牙)、GPRS无线通讯、手机短信(GSM)。

Detail Functions:

1with Instantaneous over current protection, definite time over current protection and over current protection protection;

2with Manual closed accelerating protection, the breaker will trip fast when it’s closed in fault, and it will trip and lockout close operation;

3with 0 to 4 shots reclosing, “O-t1-CO-t2-CO-t3-CO-t4-CO-lockout”,with Reclose accelerating protection, shots setting, delay time setting;

4with zero sequence over current protection, E/F, SEF;

5with cold load protection ;

6with over-voltage protection ;

7with under-voltage protection ;optional

8with electricity-running close protection ;

9with frequency protection ;

10with relay for pre-payment meter input;optional/definable

11with motor emerging failure alarm;

12Event record, Real-time sync, Real time checking,

13Optional functions:

Sectionalizing SOG protection, Double-PT, protection for CT circuit, intelligent phone control/blue booth,

GPRS communication, Mobile-phone message/GSM.