The WZ08 series is a DC charging pile designed in accordance with the standards of the State Grid. The standard version is 120kW as per the national standard.
1. Strong scalability: The charging power can be selected from 60kW to 240kW, and the charging rate of 0.5C -2C.
2. High compatibility: support the mainstream of 5 kinds of interface (GBT/CCS1 / CCS2 / CHAdeMO/NACS), the communication protocol for the current mainstream OCPP1.6 / OCPP2.0, has been adapted several charging station management platform (YKC,TELD, etc.), lithium iron phosphate batteries and ternary lithium batteries are compatible.
3. Small size, high integration: With a size of 800x650x1800, it can achieve dual-gun fast charging.
4. Customization: You can contact the customer manager to customize the color combination and advertising paint job you like.
|
Product Number |
WZ08-60kW |
WZ08-80kW |
WZ08-120kW |
WZ08-160kW |
WZ08-240kW |
WZ08-320kW |
||||
|
Input |
275-490VAC (3P+N+PE) || 50/60Hz |
|||||||||
|
Output Voltage |
200 - 1000VDC |
|||||||||
|
Output current |
200A |
250A |
||||||||
|
Max power |
60KW |
80KW |
120KW |
160KW |
240KW |
320KW |
||||
|
Connector |
GBT/CCS2/CHAdeMO/CCS1/NACS(Tesla) |
|||||||||
|
Connector number |
2 |
|||||||||
|
Efficiency |
≥94% at nominal output power |
|||||||||
|
Operating temperature |
-30°C to 55°C |
|||||||||
|
Altitude |
< 2000m |
|||||||||
|
Working || Storage Humidity |
≤ 95% RH (Non-condensing) |
|||||||||
|
Display |
7’’ LCD with touch screen |
|||||||||
|
Ingress Protection |
IP54 |
|||||||||
|
Power Electronics Cooling |
Air Cooled |
|||||||||
|
Insulation (input - output) |
>2.5kV |
|||||||||
|
Communication |
Ethernet – Standard || 3G/4G Modem (Optional) |
|||||||||
|
Electrical Safety: GFCI |
RCD 30 mA Type A |
|||||||||
|
Electrical Safety: Surge Protection |
20 kA |
|||||||||
|
Protection |
Over voltage protection, lightning protection, overcurrent protection, leakage protection, waterproof protection, etc. |
|||||||||